Products

Indoor (Wall)

PASSIVE INFRARED SENSOR PA-480S
SUPER WIDE ANGLE

NEW GENERATION WALL MOUNT PASSIVE INFRARED SENSOR

PASSIVE INFRARED SENSOR PA-480S SUPER WIDE ANGLE

Data Download

  flile type file name Download
Product pictures JPG Pic_PA-480S.jpg
Product catalogs PDF Data_PA-480S.pdf

go to page top

Feature

WALL MOUNT 180° COVERAGE

Two twin elements cover 90°each to create a full 180°pattern.
Each 90°area can be vertically adjusted up or down to create the required coverage pattern.

TROUBLE ALARM -LOW VOLTAGE-

When sensor detects a drop in supply voltage, a trouble alarm is output.
*Alarm LED selectable (ON/OFF)
*Signal count selectable (2 signals / 4 signals)
*Anti-creep zone

go to page top

Specification

Model PA-480S
Detection Passive infrared
(Twin element, pulse count)
Coverage Super wide angle
redius 8m Max (26')
Number of sensitive zone 32 pairs (64)
Mounting positions Indoor wall / pillar
Supply voltage 9.5 to 28 VDC (non-polarity)
Power consumption 20mA Max.
Alarm output Dry contact relay (N.C.)
Reset : approx. 2 sec.
24VDC (30VAC)・0.1A Max
(protective resistance 3.3Ω built-in)
Temper output Dry contact (N.C.) Ooen when cover is detached
30V ・ 0.1A Max
Alarm LED Red LED(2)
Warm up : flickering (every 0.5 sec.)
Alam : solid (approx. 2 sec.)
Trouble alam : continuous solid (LED disable)
Ttouble alarm Low power voltage : monitors drop in power voltage
Operate : initiate trouble alarm
Ambient temp. range -10℃ to +50℃ (+14F to +122F) without condensation
Wiring Terminals
Area adjustment Downward 5 positions
Weight 5.8oz. (165g)
Accessory Fixing screw : 4 × 30 2pcs.
Area lock screw : 3 × 10 1pce.

The passive infrared sensor is designed to detect infrared energy variations caused by the presence of a human body. Therefore, note that similar variations in conditions in protected area, due to other reasons, may cause the sensor to create an alarm as it is unable to distinguish between sources.

* The specifications are subject to change without notice.