Products

Indoor (Wall)

PASSIVE INFRARED SENSOR PA-470L
WIDE ANGLE / LONG RANGE

NEW GENERATION WALL MOUNT PASSIVE INFRARED SENSOR

PASSIVE INFRARED SENSOR PA-470L WIDE ANGLE / LONG RANGE

Data Download

  flile type file name Download
Product pictures JPG Pic_PA-470L.jpg
Product catalogs PDF Data_PA-470L.pdf

go to page top

Feature

QUAD ELEMENT+ NEW FUZZY LOGIC PROCESSING SYSTEM

"Fuzzy Logic" is the state-of-the-art processing system that simulates the human decision process as it compares various information such as size, temperature differential, etc. to determine the criteria for an alarm condition.
This reduces false alarm while maintaining a high detection capability.

PATTERN SELECTABLE WITH INTERCHANGEABLE LENS

Wide angle / long range pattern is selectable during installation by convenient fresnel lens replacement.
Spare long range lens is included in package.
Zone changeover switch sets the detection pattern to match the lens pattern when lens is changed.

TROUBLE ALARM -LOW VOLTAGE-

When sensor detects a drop in supply voltage, the alarm relay and LED latches in alarm until voltage is restored to its proper level.

ALARM MEMORY

Units contain special circuitry to indicate that an alarm has been activated during armed period.
Especially useful when more than one unit is used per zone.

REMOTE LED CONTROL

Enables/disables the LED via the control panel.
*Alarm LED selectable (ON/OFF)
*Alarm contact selectable (N.C./N.O.)
*Sensitivity adjustment (60%,80%,100%,120%)
*Zone changeover (Wide angle/long range)
*Anti-creep zone

go to page top

Specification

Model PA-470L
Detection Passive infrared
(Quad・Fuzzy logc)
Coverage Wide angle: 16m Max (53')
Long range: 20m Max (66')
Number of sensitive zone Wide angle: 22 paies (88)
Long range: 2 paies (8)
Mounting positions Indoor wall / pillar
Supply voltage 9.5 to 28 VDC (non-polarity)
Power consumption 25mA Max.
Alarm output Dry contact relay (N.C./N.O. selectable)
Reset : approx. 2sec.
24VDC (30VAC)・0.25A Max
(protective resistance 3.3Ω built-in)
Temper output Dry contact (N.C.) Ooen when cover is detached
30V・0.1A Max
Alarm LED Red LED
Warm up : flickering (every 0.5 sec.)
Alam : solid (approx. 2 sec.)
Memory: continuous solid
Trouble alam : continuous solid (LED disable)
Alarm memory Flickering : Memory activated
Lighting : Memory indeication
LED control Controls alarm LED
indication with terminal L / C
Ttouble alarm Low power voltage : monitors drop in power voltage
Operate : initiate trouble alarm
Ambient temp. range -10℃ to +50℃ (+14F to +122F) without condensation
Wiring Terminals
Weight 5.8oz. (165g)
Accessory Fixing screw : 4 × 30 2pcs.
Long range lens

The passive infrared sensor is designed to detect infrared energy variations caused by the presence of a human body. Therefore, note that similar variations in conditions in protected area, due to other reasons, may cause the sensor to create an alarm as it is unable to distinguish between sources.

* The specifications are subject to change without notice.

go to page top