Presence Sensor
Timer controller SAH-2(T)

Data Download
Specification
Description | Timer controller |
---|---|
Model No. | SAH-2(T) |
Power supply | 12/24VDC or 100VAC terminal type (either one) |
Current consumption | 120mA max. / 60mA at standby / 8W |
Power output | 12VDC 260mA when 100VAC powered only |
Input | Dry contact N.O. (no alarm at approx. 1 sec) |
Operation LED ①Yellow ②Green ③Red ④Red |
①LED lighting at toilet use detection(during timer counting) ②LED lighting at unuse toilet detection(during timer counting) ③LED on/off repeat every 1 sec at pre-alarm detection ④LED lighting at alarm memory (LED lighting after alarm at 3sec alarm mode) |
Timer output | Output after timer setting (and pre-alarm time) passed Presence timer: Measure the continuous input time Unuse timer: Measure the duration time of input signal Dry contact N.O. (30V 1A resistive load) |
Real time output | Linked to the sensor input time (30V 1A resistive load) *At either timer mode of Presence or Unuse and Remote OFF |
Pre-alarm output | Output at predetermined timer passed, with red LED blinking Dry contact relay N.O. (30V 1A resistive load) |
Pre-alarm function | 5min: ON/OFF |
Pre-alarm sound | Melody sound ON/OFF |
Leaving area remote input | External N.O. input make Leaving area output ON |
Leaving area remote output | Output starts at the end of Sensor input Reset by L/Remote input, Sensor input or Remote input |
Alarm mode | Hold/3sec mode changeable and memory reset by Reset slide SW |
Timer switch | Presence timer: OFF,15s,2,3,5,7,10,12,15,20,25,30,40,50,60,90m Unuse timer: OFF,15s,5m,2,3,5,6,8,9,10,11,12,15,18,24h |