Products

Presence Sensor

PRESENCE SENSOR TS-7
Round type

The TS-7 series toilet sensor is an innovative device designed to monitor toilet usage and alert users or staff in case of extended or lack of use.
Available in three variants - TS-7 (round type), TS-7U (flush mount type), and TS-7R (square type) - the sensor employs near-infrared technology to measure distances and detect occupancy, regardless of whether the user is moving or stationary.
When the user's presence exceeds a pre-set time limit, a pre-alarm is activated, followed by a main alarm to notify staff or family members if no reset action is taken. The sensor features adjustable detection angles, multiple area settings, and anti-interference design, allowing up to eight units to be installed in a single large restroom.

PRESENCE SENSOR TS-7 Round type

Data Download

  flile type file name Download
Product pictures JPG Pic_TS-7.jpg
Product catalogs PDF Data_TS-7.pdf

go to page top

Feature

DETECTION TECHNOLOGY

Utilizes near-infrared reflection to measure distances, ensuring accurate detection of both moving and stationary users.

ADJUSTABLE DETECTION

Offers nine selectable area setting patterns and adjustable detection angles (0-9 degrees), allowing for customization based on installation conditions.

MULTI-AXIS DETECTION

Features seven optical axes to measure and memorize distances to the floor or toilet seat, enabling precise occupancy detection.

POWER MODES

Supports two power modes—Power mode (requiring area setting readjustment after power outage) and Remote Controller mode (maintains settings post power outage).

PRE-ALARM AND MAIN ALARM

Initiates a pre-alarm after a preset duration of occupancy, followed by a main alarm if the user does not reset or leave, notifying staff or family members.

ANTI-INTERFERENCE DESIGN

Allows the installation of up to eight units in large restrooms without interference.

INSTALLATION FLEXIBILITY

Can be installed in various positions, even when obstructed by elements like lights, fans, doors, or handrails.

go to page top

Specification

Description Toilet occupancy sensor
Model No. TS-7 (Round)
Method Near-infrared reflection type (measure distance method)
Power supply 12~24VDC ± 10%
Current consumption 155mA or less at 12VDC
External output Dry contact relay From C, 30VDC 0.5A (resistive load)
Response time 10 sec or less
Operation LED Green LED (Initial setting: blinking, Standby: OFF, Detection: ON)
Cross talk prevention LED Orange LED (Initial setting : blinking, Main unit: OFF, Sub unit: ON)
Mounting height 2.5~3m(8.2' to 9.1')(*2.5m(8.2') for black floor, etc. with low reflectance)
Initial setting area Optical axis (5 axis) dia.: 0.25m(8.2')
Area dia.: 0.85m(2.9') (at mounting height 2.5m(8.2'))
Optical axis movement range 0.3m (0.1') in the FRONT direction at height of 2.5m(8.2'),
(by adjusting the angle in 4 steps (0/3/6/9°))
Detection output height 9 patterns by combining 3 types of area
Detection output area Optical axis (5 axis) dia.: Φ0.2m (Φ0.7')
Area dia.: 0.8m (2.7') (at detection output height 2.3m (7.6'))
Detection output height adjustment Approx. 1sec after detection and 30sec after detection completed
Switches 1) Initial setting
2) Area exclusion
3) Area invasion
Initial setting method Automatic setting by turning the power on or by using TS-A(remote controller: sold separately)
Initial setting time Approx. 30sec
Mounting position Indoor(ceiling)
Ambient temperature -10℃~+55℃ (+14℉~+131℉)
Appearance Cover plate/External cover: ABS resin(white)
Cover: polycarbonate resin
Weight Approx. 200g (7.05oz)
External dimensions 120 dia x 56.5mm (4.72" dia x 2.22")

*The figure of detection area might be changed due to affected by the color or material of the floor or cloths.

go to page top