Twin Beam
PHOTOELECTRIC TWIN BEAM SENSOR PB-60TX
UP TO 60m(200ft) OUTDOOR
New-generation TAKEX twin beam redesigned for improved
performance, easy alignment, and reduced energy consumption

Data Download
Feature
HIGHEST RELIABILITY
Double modulation technology ensures stability and reduces the possibility of unwanted activations from ambient light. In addition, 4 selectable frequencies enable multiple beam sets used in linear configurations without risk of crosstalk.
COMPACT DESIGN
PB-60TX features an all-new slim and compact design to fit modern, stylish property aesthetics.
ECO-FRIENDLY
RoHS certified and 40% reduction in current consumption compared to the conventional model.
ULTRA VERSATILE ADJUSTMENT
Featuring ±95° horizontal and ±10° vertical optical head adjustment, PB-60TX can ensure high performance intrusion detection in various applications.
PROTECTION DISTANCE CHANGEABLE
Adjustable beam power in 2 steps, 30m(100ft) / 60m(200ft) according to the protection distance to prevent wraparound and/or spill-over of the beams. PB-60TX can be flexibly adapted to relocation or layout changes.
ALARM OUTPUT OPERATION CHANGEABLE
PB-60TX includes a secondary real-time alarm output mode suitable for alternative applications including people counting.
OTHER FUNCTIONS
Enhanced features include a drip-proof housing designed to channel precipitation away from the face of the beam, anti-bird spikes (option) to prevent our feathered friends from alighting on the units and a sound check function for easy alignment.
Specification
Model | PB-60TX |
---|---|
Detection system | Near infrared pulsed beam interruption system (TR-RE 2 beam simultaneous interruption) |
Protection distance | Outdoor 60m (200') or less |
Distance margin (maximum arrival distance) |
10 times 600m (2000') |
Protection distance setting | 30m (100'), 60m (200') (2 distances selectable) |
Response time | 0.05sec., 0.1sec., 0.25sec., 0.7sec. (4-level changeover) |
Power supply voltage | 10~28V DC (non-polarity) |
Current consumption | 37mA (max.) |
Alarm output | Dry contact(semi-conductor) output : N.C./N.O. selectable ・Contact capacity : 30V (AC/DC) 0.25A max. (Resistive load) Protective resistor ・Contact operation : Standard / Real time selectable (Dip switch) Standard : Interruption time (Min. 2sec.) Real time : Interruption time |
Tamper output | Dry contact relay output : N.C. ・Contact capacity : 30V (AC/DC) 0.1A (Resistive load) Protective resistor ・Contact operation : Activated when the cover is detached |
Transmission LED | Red LED (Transmitter) : ON when powered (when the cover is open) |
Alarm/sensitivityattenuation LED | Red LED (Receiver) : ON when an alarm is output / Blinks when beam is attenuated |
Functions | Modulation frequency selectable, Tamper, Response time adjustment, Monitor jack, Sound check |
Beam adjustment | Horizontal : ± 95° Vertical : ± 10° |
Ambient temperature | –25°C to +60°C (–13°F to +140°F) (No freezing or condensation) |
Mounting position | Outdoor, Indoor IP 55 |
Wiring | Terminals |
Weight | Transmitter : 380g (13.1oz) Receiver : 400g (14.1oz) |
Appearance | Cover : Resin (Wine red) Base : Resin (Black) |