Products

Flame Passive Sensor

FLAME PASSIVE SENSOR FP-5500E

IDEAL COMBINATION SENSOR, DETECTING FLAME [Max.15m (50ft.)]
AND INTRUSION [Wide angle 15m(50ft.)] , MINIMIZES NUISANCE
ALARM AND REALIZES SAFER OUTDOOR PROTETION.

FLAME PASSIVE SENSOR FP-5500E

Data Download

  flile type file name Download
Product pictures JPG Pic_FP-5500E.jpg
Product catalogs PDF Data_FP-5500E.pdf

go to page top

Feature

TWO OUTPUT MODES SELECTABLE

Two output modes are available; "AND" detection mode and "Individual" detection mode.
• In "AND" detection mode, an alarm signal is output when both flame and passive infrared sensor detect during the selected AND timer.
• In "Individual" detection mode, flame or passive alarm signal is output when either the flame sensor or passive sensor detects.

FORCED OUTPUT OPERATION

The flame sensor outputs flame alarm signal after continued detection for a certain period of time, or detects twice during the selected AND timer even in "AND" detection mode, without any detection by passive sensor.

ALARM MEMORY

The activated sensor can be easily identified by Alarm memory indication (flame and passive sensor individually).
Memory LED blinks for 3 min. and lights on for 47 min. after alarm activation.

SENSIVITY ADJUSTMENT (Passive Sensor)

For outdoor operation in "Individual mode", the sensitivity adjustment enables reliable discrimination between human body and other objects depending on the environment.
<20 / 50 / 80 / 100%>

[Recommended setting]
AND mode : 100%.
Individual mode : 20%, 50%, 100%.

OPERATION SET-UP BY DETECTION TIMER (Flame Sensor)

The alarm will be activated only when the sensor detects a flame (ultraviolet rays) for longer than set time.
Four detection times are selectable by DIP switch on the sensor.
< 1 / 3 / 6 / 15sec.>

[Recommended setting]
AND mode : 1sec.
Individual mode : 3sec. 6sec. 15sec.

ANGLE ADJUSTMENT

Three-part rotation mechanism enables adjustment in various angles.

go to page top

Specification

Model FP-5500E
【Flame sensor】
Detection system Ultraviolet rays (Detection wave length 185 to 260nm)
Detection distance 15m(50') :15cm(5.90'') flame on 4cm (1.57'') square pan in front
10m(33') : 7cm(2.75'') lighter flame in front
Detection area angle Approx. 120° conically
Detection setting Detection timer : 4steps (1sec, 3sec, 6sec, 15sec)
Detection sensitivity : (H [100%], L [50%])
*Selectable only in "AND" mode
(Fixed to H [100%] in "AND" mode
Alarm LED (RED) Inside front window
• Lighting at alarm
(Detection time + off delay. Approx. 2 sec.)
*Blinking (3 min) / Lighting (47 min) at memory
【Passive sensor】
Detection system Passive infrared
Detection area angle Wide Angle 15m (50') Max
Sensitivity setting 4 steps (100%, 80%, 50%, 20%)
Alarm LED (RED) Inside front window
• Lighting at alarm
(Detection time + off delay. Approx. 2 sec.)
*Blinking (3 min) / Lighting (47 min) at memory
【Power supply】 10V to 30VDC (non-polarity)
【Power consunmption】 25mA Max.
【Alarm① output】
Contact operation 【AND mode】
• When flame sensor detects twice within set “AND” timer,
(Detection time after 2nd detection + off delay. Approx. 2 sec.) or
• When flame sensor detects for “Flame duration time”
(Detection time after 30/60 sec + off delay. Approx. 2 sec.)
【Individual mode】
• When flame sensor detects (Detection time + off delay. Approx. 2 sec.)
Contact method Dry contact relay (Semi-Conductor) (N.C. / N.O. selectable)
Contact capacity 30V (AC/DC) 0.25A Max. (resistive load)
【Alarm② output】
Contact operation 【AND mode】
• When both flame and passive sensor detect within set “AND” timer
(Detection time (2 sec Min.)
【Individual mode】
• When passive sensor detects (One shot. Approx. 2 sec)
Contact method Dry contact relay (Semi-Conductor) (N.C./N.O. selectable)
Contact capacity 30V (AC/DC) 0.25A Max.(resistive load)
【Alarm memory】 Reset after blinking (3 min) and lighting (47 min)
(Operative individually with flame and passive sensors)
* No indication when Alarm LED is off
【Ambient temperature range】 -20°C to + 50°C (-4°F to + 122°F)
without condensation and freeze
【Mounting position】 Indoor / outdoor (IP43)
【Connections】 Lead wire [Cord length : 0.5m (20")](6 cores : 2×power, 4×alarm)
【Weight】 Approx. 550g (including flange)
【Appearance】 Body : Resin (Black)

The specifications are subject to change without notice.