Products

Indoor (Ceiling)

PASSIVE INFRARED SENSOR PA-5312E
Wide angle protection/Coverage 12m

Quad elements coupled with “Fuzzy logic” signal processing (discriminating temperature differential information and object size) provide high “catchability”. The series offers several unique features that make this sensor a desirable choice for high security applications.

PASSIVE INFRARED SENSOR PA-5312E Wide angle protection/Coverage 12m

Data Download

  flile type file name Download
Product pictures JPG Pic_PA-5312E.jpg
Product catalogs PDF Data_PA-5312E.pdf

go to page top

Feature

HIGH PERFORMANCE

Dual twin element, optical unit and signal processing circuitry enable high density protection area. Ceiling/wall mountable.

SLIGHT MOTION DETECTION

The unit can be adjusted from quad element sensing to twin element sensing, which doubles the number of sensitive zone, suited for situations where close range detection is desirable. (Highest sensitivity setting)

SELF-TEST FUNCTION

The unit performs a self-checkup of alarm contact whenever an alarm is indicated. The alarm LED flashes if the contact is short-circuited, or damaged by induced lightening, etc.

BUILT-IN ALARM MEMORY

Memory LED indicates which sensor triggered an alarm during armed condition when two or more sensors are connected on the same line.

TROUBLE ALARM

The trouble found out is notified by continuous alarm output and lighting of alarm LED.

●Unit trouble :
 When inner circuit / wiring is damaged or broken.
●Low voltage :
 When the supply voltage drops down to approx. 8.5V DC.
●Positioning :
 When the sensor head fails to return automatically after adjustment is completed.

go to page top

Specification

Model PA-5312E
Detection system Passive infrared (Quad)
Coverage Wide angle protection 40' (12m) Max.
Sensitive zone 18 pairs (72)
Alarm output Dry contact relay output: N.O. or N.C. selectable
Reset time: approx. 2sec.
24V (AC/DC) 0.25A Max
Supply voltage 9.5V to 30V DC (non-polarity)
Power consumption 25mA
Features Fuzzy Logic
Trouble Output
・ Unit trouble
・ Low voltage
・ Positioning

Indication of Malfunction
・ Self-check up of alarm contact output
Ambient temperature -10℃ to +55℃
Mounting position Ceiling, wall (indoor)
Optional Flush mount attachment
External dimensions 147.3mm dia × 59mm
Weight 250g

* The specifications are subject to change without notice.

go to page top